Lightweight High-strength 182 PERC Solar Modules
ALP lightweight solar panels, using aerospace-grade composite materials and flexible film technology, weigh only 4.7kg/m² (1/5 of traditional solar panels) and are designed for load-limited roofs, mobile equipment, and special scenarios. The lightweight solar panel complies with the strict environmental tests of IEC61215, and can operate stably in a 15-level typhoon, -40℃ extreme cold, and salt spray corrosion environment, and the power output is guaranteed to be ≥84.8% for 25 years.
Max-Power
420W
Module Efficiency
21.6%
Power Tolerance
0~+5W
NMOT
43±2℃
Solar Panel Size
Features & Benefits
Lightweight Design
4.7kg/m² weight matches various requirements for the low-load roof.
High Strength
The surface is made of ultra-thin tempered glass, which has the characteristics of good hail impact resistance and strong load capacity.
High Efficiency
High light transmittance performance with more than 3% higher power than similar products brings more power generation and higher income.
Stable and Reliable Characteristics
Meet the IEC61215 stringent environment test with low
attenuation characteristics.
Convenient Installation
Multiple installation methods, pasted fixed, or dismountable lock block fixed.
Safe and Reliable
Prevent dust stratification, lightweight and safe, convenient operation and maintenance.
Reinsurance Coverage For 25 Years
12-year
Quality Warranty
25-year
Performance Warranty
LLOYD'S
Insured by LLOYD'S
Within the first year from the date of installation and normal operation, the output power shall not be less than 98% of the solar panel's minimum output power as outlined in the specifications. Afterwards, maximum 0.55% output decrease per year. After 25 years, the solar panel's output power shall not be less than 84.8% of its minimum output power as outlined in the specifications.
Reliability & Durability Tests

Fire Resistance Test
Ensure that the lightweight solar panels meet the highest fire safety requirements when integrated into buildings, reducing the risk of fire.

Hail Impact Test
The solar panels can withstand extreme weather and pass the impact test equivalent to hail the size of a golf ball.

Mechanical Load Test
Ensure that the solar panels maintain structural integrity in extreme climates such as blizzards/ typhoons.

Hot Plate Durability Test
Verify the durability of the solar panels under the temperature difference between day and night/seasons to prevent the hidden cracks of the cells and the failure of the packaging materials.

Surface Scratch Test
Ensure that the surface damage of the solar panels during transportation/installation will not affect the long-term performance.

UV Aging Test
Prevent aging problems such as yellowing of the packaging material and EVA delamination, and ensure the power generation efficiency of the solar panels throughout their life cycle.
Comprehensive Qualifications & Certifications
ISO 9001
2015 Quality Management System
ISO 45001
2018 Occupational Health and Safety Management System
ISO 14001
2015 Environment Management System
Electrical Characteristics at Standard Test Conditions(STC)
Spec/Model | Unit | SSD405AH5T | SSD410AH5T | SSD415AH5T | SSD420AH5T |
Max-Power(Pm) | W | 405 | 410 | 415 | 420 |
Power Tolerance | W | 0-+5 | |||
Max-Power Voltage(Vm) | V | 31.12 | 31.28 | 31.45 | 31.66 |
Max-Power Current(Im) | A | 13.04 | 13.13 | 13.22 | 13.29 |
Open-Circuit Voltage(Voc) | V | 37.00 | 37.20 | 37.40 | 37.60 |
Short-Circuit Current(Isc) | A | 14.04 | 14.10 | 14.16 | 14.22 |
Effective Module Efficiency(nm) | % | 20.9 | 21.2 | 21.4 | 21.6 |
STC: AM=1.5,Irradiation 1000W/m2,Module Temperature25C Power Tolerance ±3% |
Electrical Characteristics at Nominal Module Operating Temperature(NMOT)
Spec/Model | Unit | SSD405AH5T | SSD410AH5T | SSD415AH5T | SSD420AH5T |
Max-Power(Pm) | W | 306 | 310 | 314 | 318 |
Max-Power Voltage(Vm) | V | 28.9 | 29.1 | 29.3 | 29.5 |
Max-Power Current(Im) | A | 10.61 | 10.67 | 10.73 | 10.79 |
Open-Circuit Voltage(Voc) | V | 34.8 | 35.0 | 35.2 | 35.4 |
Short-Circuit Current(Isc) | A | 11.22 | 11.28 | 11.32 | 11.36 |
NMOT: Irradiation 800W/m², Ambient temperature20℃, Wind Speed 1m/s |
Temperature Coefficient
Nominal Module Operating Temperature | 43±2℃ |
Temperature coefficient of Pmax | -0.35%/℃ |
Temperature coefficient of Voc | -0.26%/℃ |
Temperature coefficient of lsc | 0.048%/℃ |
Operating Conditions
Max. System Voltage | DC1500V(IEC) |
Max. Series Fuse Rating | 25A |
Operating Temperature Range | -40℃~+85℃ |
Mechanical Characteristics
Installation Module Dimension (LXWXH) | 1716mmx1128mmx2.2mm |
Weight | 9.1kg |
Glass Type | High Transmittance Tempered Glass |
Cell (quantity/ material/ type/ dimensions) | 108(6x18)/ Mono/ 182*91mm |
Encapsulant | POE |
Junction Box (protection degree) | IP68 |
Cable (length/cross-sectional area) | Customizable/4m㎡ |
Connector | MC4 Compatible |
Max Load | 2400Pa/2400Pa |
Package
Transportation | Container Size | Quantity(pcs) | Quantity(per pallet) |
Container | 40'HQ | / | / |
Platform Trailer | 13m | 1120 | 40 |
Platform Trailer | 17.5m | 1440 | 40 |
I-V Curve